EN
Services
Precision manufacturing. Stronger together.Manufacturing Services & Support

From prototype to production, coordinated manufacturing solutions for your custom parts.

View All Services →
Solutions

Thermal Technologies

Choose air- or liquid-cooling components around your thermal and mechanical requirements.

Stepped aluminum heat sink with copper contact insert — illustrative concept
Explore Thermal Technologies

Heat Sinks

Liquid Cooling

AI & Data Center Cooling

Manufacturing support for your cold plates, manifolds and cooling assemblies.

Processor cold plates and distribution manifold — illustrative concept
Explore AI Cooling

AI Compute Cooling

Distribution & Assembly

AI Cooling Interfaces
  1. Cold PlateHeat-source interface
  2. ManifoldCoolant distribution
  3. CDU InterfaceConnection requirements
  4. Rack / LoopAssembly integration
Review component fit across your cooling system.

Industry Cooling Solutions

Find components for your power electronics, energy, laser and telecom application.

Machined power module cooling plate — illustrative concept
Explore Industry Cooling

Power Electronics

EV & Energy

Laser & Telecom

Industries

High-Tech & Electronics

Components for your electronic systems.

View Industry Applications

Applications & Project Inquiries

Precision & Advanced Systems

Start with your functional and quality requirements.

View Industry Applications

Applications & Project Inquiries

Industrial & Energy

Build around your operating environment.

View Industry Applications

Applications & Project Inquiries

Materials

From prototype to production, review material performance, manufacturability and cost for your part.

Engineering Plastics

Match your polymer to function, process and environment.

→
ABS — illustrative material conceptABSReview enclosure and molding needs›Polycarbonate (PC) — illustrative material conceptPolycarbonate (PC)Discuss clarity and impact needs›Nylon (PA) — illustrative material conceptNylon (PA)Review moisture and wear conditions›POM / Acetal — illustrative material conceptPOM / AcetalReview fit and sliding features›PEEK — illustrative material conceptPEEKDiscuss operating conditions›PTFE — illustrative material conceptPTFEReview friction and chemical exposure›ULTEM / PEI — illustrative material conceptULTEM / PEIDiscuss thermal and electrical needs›

Elastomers & Specialty Materials

Confirm grade availability and application requirements.

→
Elastomers
Silicone / LSR — illustrative material conceptSilicone / LSRDiscuss flexible component needs›TPU / TPE — illustrative material conceptTPU / TPEReview flexibility and processing›EPDM — illustrative material conceptEPDMReview weathering and chemical exposure.›NBR — illustrative material conceptNBRReview oil and fuel exposure.›FKM — illustrative material conceptFKMReview temperature and chemical exposure.›
Specialty Materials
G10 / FR4 — illustrative material conceptG10 / FR4Review insulation and laminate needs›Composites — illustrative material conceptCompositesReview stiffness, weight and laminate.›Customer-Specified MaterialsConfirm your grade and requirements.›Other Specialty MaterialsDiscuss your application and grade.›
Resources

Design & Engineering

Practical guidance for your part geometry and material decisions.

Explore Design Resources

Cost & Planning

Prepare your process, budget and sourcing questions.

Explore Planning Topics

Learn & Proof

Build your knowledge before production.

Explore Learning Paths
About Us

About LK MFG

Learn who we are and how we operate.

Explore Company Information →

Get in Touch

Find our U.S. support team or start a conversation.

View All Company Information →
sales@lkmfg.com (945) 409-1013

1750 Briercroft Ct, Suite 204
Carrollton, TX 75006, USA

Bare server chassis with rack mounting ears and a separate perforated cover; illustrative component concept, not a customer part or company test record

YOUR CHASSIS. YOUR RAILS. YOUR SERVICE SPACE.

Custom Data Center Hardware for Your Server & Rack Interfaces

Review your chassis, mounting brackets and cable-support parts around the installed assembly. When choosing a custom server chassis manufacturer, share the released drawing, mating hardware and acceptance requirements together.

4 Interfaces to Confirm Before You Release Your Chassis

01 · Rack envelope

State the allocated U height and actual usable depth.

02 · Rail & mounting

Identify mating rail kits, rack ears and fastening access.

03 · Air & cables

Reserve openings, connector space and service access.

04 · Finish & records

Define protected contacts, appearance and sample evidence.

For your data center rack hardware manufacturer review, distinguish the fabricated component from complete server, rack and electrical-system approval.

Choose the Hardware Scope for Your Assembly

Chassis trays & covers

Review formed edges, removable covers, standoffs and cable openings.

Your input: assembly envelope, material, thickness and released revision.

Custom server mounting brackets

Match rack ears, locating slots and fastening faces to the actual mounting hardware.

Your input: mating rail model, hole pattern and installed loading requirements.

Cable & power supports

Identify cable-management brackets, support plates and protected connection areas.

Your input: routing, bend clearance, insulation interfaces and assembly sequence.

Manufacturing scope is confirmed from your part. Rack load, EMC, electrical safety and thermal performance need their own defined approval.

Compare Rack Height Without Losing Sight of Depth

U height tells you the nominal vertical allocation. It does not confirm your chassis depth, rail-kit range, rear connector clearance or door access.

Nominal rack-space height

1U = 44.45 mm · zero baseline, 0–180 mm

Height = U × 44.45 mm. These are rack-space references, not finished chassis dimensions or LK MFG tolerances. Allowances and mounting details follow your selected equipment specification.

4 Dimensions Your Drawing Still Needs

  1. Front-to-rear mounting-plane spacing.
  2. Rail kit adjustment and extension range.
  3. Chassis body depth plus rear cables and plugs.
  4. Service clearance and door/PDU interference.

A nominal 19-inch interface does not establish the outside width of a cabinet or guarantee compatibility.

Reference: Vertiv rack catalogue · page6 installation units → Only unit geometry is used; no supplier load, cooling or delivery claim is transferred to your project.

Match Your Rail Kit Before You Add Mounting Holes

For custom server mounting brackets, identify which surfaces locate the chassis and which fasteners only clamp it.

  • Confirm front and rear rack mounting positions.
  • Review slot travel, hole access and tool clearance.
  • Check insertion, removal and full-extension service access.
  • Keep critical mounting faces clear of unintended coating buildup.

Share the mating rail drawing or approved interface dimensions. A product name alone may not define the installed geometry.

Review formed hardware →
Distinct rack mounting brackets and a telescoping rail interface with elongated mounting slots; illustrative component concept, not a customer part or company test record

Compare Processes Around Your Geometry & Quantity

For server chassis sheet metal fabrication, review bend access, formed dimensions and joining before choosing the production route.

Your part featureRoute to reviewDecision for your drawing
Thin trays, covers and mounting earsLaser cutting and formingThickness, bend orientation, hardware and edge requirements
Locating blocks or close mating facesCNC machiningDatums, tool access and critical dimensions
Repeated lengthwise rail or support sectionExtrusion plus secondary machiningExisting/new profile, cut length and end features
Multi-part frame or bracket groupJoining and assemblyFixtures, distortion control and final mating checks

Tooling investment, economical quantity and lead time require your geometry and order scope; no universal break-even quantity is implied.

Define Finish, Contact Areas & Electrical Scope Together

Sheet-metal grade & condition

State the governing material specification, thickness, finish and cosmetic faces. Confirm substitutions before manufacture.

Coating & bonding faces

Mark masked contacts, threads and mating surfaces. Define the required bonding verification with the assembly owner.

Copper busbars for data centers

Review grade, bend geometry, hole pattern, coating and insulation interfaces. Ampacity, temperature rise and electrical safety cannot be inferred from a material certificate or appearance.

Material properties alone do not establish an assembly rating. Define electrical and mechanical acceptance separately.

Server chassis tray with accessible datum holes reviewed by a CMM touch probe; illustrative component concept, not a customer part or company test record

Approve the Assembled Fit & the Records You Need

01 · Drawing

Released revision, mating dimensions and assembly configuration.

02 · Sample

Rack ears, cover fit, fastener access and selected interfaces.

03 · Finish

Agreed appearance sample, protected contacts and packing.

04 · Report

Required dimensions, sampling and agreed inspection records.

A dimensional report does not validate complete server performance, EMC, electrical safety or rack loading.

Review inspection documentation →

6 Inputs for Your Hardware Review

  1. CAD and controlled drawing revision.
  2. U allocation, usable depth and mating rail details.
  3. Material grade, sheet thickness and final condition.
  4. Coating, masked contacts and appearance sample.
  5. Sample quantity and expected repeat demand.
  6. Inspection, assembly and packing requirements.

Answers Before You Specify

Do standard U heights guarantee that my chassis fits?

No. Compare the nominal allocation with the actual chassis dimensions, rail kit, hole pattern and required clearances. Use your released interface specification.

What information is needed to quote custom server hardware?

Provide the CAD model, controlled drawing and revision, material and thickness, finish and masking requirements, trial and repeat quantities, mating hardware and required records.

Can coating affect rack and chassis fit?

Review the specified coating on mounting faces, holes, threads and bonding contacts. Confirm masking and final-condition acceptance before sample approval.

Does LK MFG supply a complete certified data center rack or server?

This page concerns manufactured components reviewed to your drawing. Complete-system design, ratings, certification and approval remain a separately defined project scope.