Heat Sinks

Liquid Cooling

AI & Data Center Cooling

Manufacturing support for your cold plates, manifolds and cooling assemblies.

Processor cold plates and distribution manifold — illustrative concept
Explore AI Cooling

AI Compute Cooling

Distribution & Assembly

AI Cooling Interfaces
  1. Cold PlateHeat-source interface
  2. ManifoldCoolant distribution
  3. CDU InterfaceConnection requirements
  4. Rack / LoopAssembly integration
Review component fit across your cooling system.

Industry Cooling Solutions

Find components for your power electronics, energy, laser and telecom application.

Machined power module cooling plate — illustrative concept
Explore Industry Cooling

Power Electronics

EV & Energy

Laser & Telecom

Industries

High-Tech & Electronics

Components for your electronic systems.

View Industry Applications

Applications & Project Inquiries

Precision & Advanced Systems

Start with your functional and quality requirements.

View Industry Applications

Applications & Project Inquiries

Industrial & Energy

Build around your operating environment.

View Industry Applications

Applications & Project Inquiries

Materials

From prototype to production, review material performance, manufacturability and cost for your part.

Engineering Plastics

Match your polymer to function, process and environment.

→
ABS — illustrative material conceptABSReview enclosure and molding needs›Polycarbonate (PC) — illustrative material conceptPolycarbonate (PC)Discuss clarity and impact needs›Nylon (PA) — illustrative material conceptNylon (PA)Review moisture and wear conditions›POM / Acetal — illustrative material conceptPOM / AcetalReview fit and sliding features›PEEK — illustrative material conceptPEEKDiscuss operating conditions›PTFE — illustrative material conceptPTFEReview friction and chemical exposure›ULTEM / PEI — illustrative material conceptULTEM / PEIDiscuss thermal and electrical needs›

Elastomers & Specialty Materials

Confirm grade availability and application requirements.

→
Elastomers
Silicone / LSR — illustrative material conceptSilicone / LSRDiscuss flexible component needs›TPU / TPE — illustrative material conceptTPU / TPEReview flexibility and processing›EPDM — illustrative material conceptEPDMReview weathering and chemical exposure.›NBR — illustrative material conceptNBRReview oil and fuel exposure.›FKM — illustrative material conceptFKMReview temperature and chemical exposure.›
Specialty Materials
G10 / FR4 — illustrative material conceptG10 / FR4Review insulation and laminate needs›Composites — illustrative material conceptCompositesReview stiffness, weight and laminate.›Customer-Specified MaterialsConfirm your grade and requirements.›Other Specialty MaterialsDiscuss your application and grade.›
Resources

Design & Engineering

Practical guidance for your part geometry and material decisions.

Explore Design Resources

Cost & Planning

Prepare your process, budget and sourcing questions.

Explore Planning Topics

Learn & Proof

Build your knowledge before production.

Explore Learning Paths
About Us

About LK MFG

Learn who we are and how we operate.

Explore Company Information →

Get in Touch

Find our U.S. support team or start a conversation.

View All Company Information →
sales@lkmfg.com (945) 409-1013

1750 Briercroft Ct, Suite 204
Carrollton, TX 75006, USA

YOUR INTERFACES · YOUR CONDITIONS · YOUR ACCEPTANCE

Inverter Cooling
for Your Loss Map, Module Layout & Installed Conditions

Define your inverter cooling component around the actual heat losses, module layout and available airflow or coolant. Review the shared baseplate, mounting datums, contact stack and delivered manufacturing scope before approving the sample.

Illustrative inverter cooling assembly concept, not a customer part

Illustrative component concept

Drawing

Critical geometry & interfaces

Materials

Grades, condition & compatibility

Interfaces

Defined route & final state

Evidence

Agreed methods & records

Start with Your Loss Map and Installed Interfaces

Define the heat-source layout, contact plane, installation and sample evidence together.

  • Map losses and selected module instructions
  • Define installed airflow or coolant conditions
  • Review contact, mounting and coolant or airflow
  • Agree component and platform acceptance separately
  • Confirm the sample and acceptance evidence
Illustrative loss map and operating cycle concept, not documentary company or customer photography

Loss map and operating cycle

Share the loss distribution across your power devices and other heat sources, switching conditions, duty cycle and temperature limits. Define the validation owner and the installed operating cases, including sustained load and relevant transients.

Illustrative module layout and mounting concept, not documentary company or customer photography

Module layout and mounting

Your inverter cooling mounting interface should identify exact module part numbers, contact footprints, TIM, electrical isolation responsibility and fasteners. Define inverter cold plate mounting holes, datums, adjacent keep-outs and service access on the controlled drawing.

Illustrative air or coolant boundary concept, not documentary company or customer photography

Air or coolant boundary

For an air-cooled part, specify available airflow and the enclosure. For a liquid-cooled part, state fluid, inlet temperature, flow and allowed inverter cooling plate pressure drop at named measurement points. Mark which fittings, seals and brackets are supplied.

Illustrative quote and sample evidence concept, not documentary company or customer photography

Quote and sample evidence

When selecting an inverter cold plate manufacturer, compare the supplied part boundary and evidence against your drawing. Your custom inverter cold plate quote should identify material, manufacturing route, final surface state, quantities and dimensional, leak and separate performance checks.

Illustrative engineering concepts

Compare 4 Cooling Component Routes for Your Inverter

Choose a route against the actual module and installed conditions. These concepts do not establish package compatibility, an operating power range or complete converter qualification.

Illustrative engineering concepts

Choose Your Inverter Cooling Route from the Loss Map

HEAT MAP & INTERFACES↓COMPONENTS & CONNECTIONS↓SAMPLE & AGREED CHECKS↓APPROVED FINISHED PART

For inverter liquid cooling, share the heat-source locations, dissipated losses, fluid, inlet temperature and flow allowance. An inverter heat sink prototype needs the installed airflow, enclosure clearances and fin direction. Keep inverter cooling thermal resistance tied to named temperature nodes and the specified configuration; output power alone does not define the cooling requirement.

  • Define the supplied parts, material and connection boundary.
  • Review your critical interfaces in their final production state.
  • Agree sample evidence before repeat-order release.
Compare thermal technology routes →

Reference context: SEW-EURODRIVE cold-plate installation — size 0 scope → · MathWorks inverter liquid-cooling model overview →. Follow the current documentation for your exact equipment and modules; no package-specific limits or simulation results are adopted here.

Compare Your Cold-Plate Material References

Compare bulk conduction and mass alongside your module contact stack, coolant, coatings and manufacturing route. These references are not finished inverter cooling tests or material substitution approvals.

Typical thermal conductivity

6061-T6 · 25°C167 W/(m·K)
Cu-ETP annealed · 20°C394 W/(m·K)

Hydro 6061-T6 at 25°C. KME Cu-ETP annealed at 20°C.

Density reference

60612.7 g/cm³
Cu-ETP8.92 g/cm³

Calculate finished mass from the actual geometry. A material conductivity difference does not establish a device-temperature reduction.

Selected composition limits · weight %
GradeEuropean referenceSiFeCuMnMgZnAl
6061EN AW-6061 · AlMg1SiCu0.40–0.80≤0.700.15–0.40≤0.150.80–1.20≤0.25Balance
C11000Cu-ETP · CW004A——≥99.90————

Selected elements only. Dash means not specified in this summary, not zero. 6061: Cr 0.04–0.35%, Ti ≤0.15%; C11000: O ≤0.040%; do not relabel Cu-ETP as oxygen-free copper. Aluminum other elements ≤0.05% each / ≤0.15% total. The purchasing standard and certificate govern. Confirm product form, temper, joining compatibility and required final condition.

Sources: Hydro 6061 → · KME Cu-ETP →

3 Views of Your Inverter Cooling Decision

Compare the loss allocation, installed boundary and approval evidence. The chart is a chosen arithmetic example, not a product rating or measured inverter test.

1 · Allocate the chosen losses

Module position A120 W
Module position B180 W
Module position C300 W

Chosen example: 120 + 180 + 300 = 600 W across three module locations. Their shares are 20%, 30% and 50%. These chosen losses are not an inverter output rating, typical efficiency or LK MFG capability. Replace them with your controlled loss map and relevant operating cases.

2 · Define the installed boundary

MODULE FOOTPRINTS + SHARED CONTACT PLANE↓AIRFLOW OR COOLANT + INLET CONDITIONS↓ENCLOSURE + CONNECTIONS + SERVICE ACCESS

Review obstruction, recirculation or flow routing in the actual installation. A bench setup does not automatically reproduce the converter enclosure or hydraulic circuit.

3 · Approve separate evidence

DIMENSIONS + JOINING + CLEANLINESS↓DEFINED LEAK / PRESSURE BOUNDARY↓THERMAL + HYDRAULIC + ELECTRICAL OWNERS

Agree the configuration, loss map, sensors, mounting, interface materials and operating cases. A dimensional report or leak record does not establish installed module temperatures.

Review Your Surface and Cleanliness Requirements

Separate your thermal contact faces, sealing interfaces and wetted passages. Confirm the specified final condition with the mating assembly.

Illustrative solid module contact land on an inverter cold plate concept, not documentary company or customer photography

Define the module contact area and final surface inspection state from the released drawing.

A finish is not a universal cooling improvement. Confirm its purpose, compatibility and inspection state. Review surface finishing options →

Illustrative engineering concepts

Define Your Functional Features

Put the dimensions that control sealing, assembly fit and heat transfer on your drawing.

Illustrative sectioned inverter cold plate passage and solid contact land concept, not documentary company or customer photography

Illustrative inverter cold plate section concept

Contact footprint

Module loss map, selected TIM and approved clamping stack

Ports and seals

Thread designation, seal land and fitting engagement

Mounting datums

Hole pattern, datum scheme and tool access

Cover and passages

Joining access, wall thickness and cleaning scope

Final condition

Flatness, masking, protected interfaces and inspection state

Resolve 6 Design Risks Before Your Order

Resolve contact flatness, TIM and isolation responsibility, connection checks, material, operating conditions and approval evidence.

Shared mounting plane

Specify inverter cooling plate flatness and inspection area from the selected modules and released mounting documentation. Review the final joined and machined state, the shared mounting plane and the actual clamping stack; one package limit is not universal.

Your input

Controlled drawing and the relevant service conditions.

Your acceptance

Agreed method, inspection state, limits and required records.

Illustrative shared mounting plane review for inverter cooling components concept, not documentary company or customer photography

Illustrative engineering concept

5 Checkpoints from Drawing to Repeat Supply

Drawing review

Confirm revision, interfaces and operating inputs.

Route review

Agree materials, joining and final machining.

Sample build

Review the finished component and assembly fit.

Agreed checks

Assess specified dimensions, joints and test records.

Production release

Release the accepted revision, packaging and repeat-order scope.

Approve Your Baseplate Geometry and Installed Validation Separately

Illustrative inverter cooling dimensional inspection concept, not a customer part

Illustrative component concept

Your sample records should connect the inverter loss map and module positions to the released plate drawing, material and final contact surfaces. Agree dimensions, joining records, cleanliness and specified leak checks. Module-temperature, hydraulic and electrical acceptance require their own conditions and approval owners.

  • Material identity and drawing revision
  • Module contact face, mounting datums and ports
  • Specified joining and test evidence
  • Contact-face and port protection, packaging and release
Review quality requirements →

Match Your Cooling Part to the Released Power Module

These are component review contexts, not customer cases, automotive qualification, certified converters or endorsed package compatibility.

Illustrative generic inverter modules on a closed cold plate integration fixture concept, not documentary company or customer photography

Industrial drives

Review the selected module loss map and installed cooling route.

Power converters

Control contact footprint, mounting and nearby keep-outs.

Renewable power equipment

Define operating conditions and the approval owner.

Charging power stages

Review coolant connections or available airflow.

Traction component prototypes

Match the released module interfaces and supplied part scope.

Power supply modules

State exact footprints and the dissipated losses.

Validation fixtures

Control TIM, mounting, sensor positions and operating inputs.

Replacement cooling parts

Match the exact module and installed revisions.

Compare thermal manufacturing routes →

6 Inputs for Your Inverter Cooling Quote

  1. Loss map + duty cycle and installed operating cases
  2. Exact module part numbers + current mounting instructions
  3. Contact stack, TIM + isolation responsibility
  4. Baseplate datums, holes, keep-outs + service access
  5. Available airflow or coolant, inlet temperature + flow allowance
  6. Material, quantities + sample evidence and validation owner

Ask your quote to separate component manufacturing, joining, finishing, inspection and any independently agreed validation. The drawing review confirms availability, quantities and delivery scope.

Answers Before You Specify

What inverter data is needed for a custom cooling plate quote?

Provide the controlled plate and assembly drawings, exact module part numbers and mounting instructions, heat-source loss map, temperature limits, operating cycle, contact stack, installed air or coolant conditions, quantities and required sample evidence. Identify the supplied manufacturing boundary.

When should an inverter cooling plate move from prototype to production?

Release the accepted drawing revision after reviewing sample dimensions, mounting fit, material, joining and the specified records. Complete separately agreed thermal, hydraulic and electrical validation for the installed configuration. A visually acceptable sample alone is not production approval.

Does inverter cooling require the same design for IGBT and SiC modules?

No universal shared design can be assumed. Review each selected package, loss map, switching conditions, mounting instructions and interface stack. A change of semiconductor technology may also change the module layout and installed cooling boundary; revalidate the affected interfaces.

Which acceptance tests are needed for an inverter cold plate sample?

Agree material identity, final contact geometry, mounting and port dimensions, fit, cleanliness and any specified leak or pressure checks. Define hydraulic, thermal and electrical validation separately, with operating inputs, sensor locations and approval responsibilities.

Can the inverter output rating be used as the heat load?

Use the relevant dissipated losses and heat-source distribution. Electrical output is not the same quantity as heat entering the cooling component. Share the operating cases and calculation or measurement basis, including the relevant duty cycle and switching conditions.

Will adding external fins or a fan guarantee lower module temperatures?

No. The complete heat path, contact stack, enclosure and installed flow determine the result. Review the approved equipment configuration and validate the actual module temperatures; an exterior surface temperature or photograph does not establish junction conditions.