Injection Molding
Tooling and molding for your repeat plastic parts.
From prototype to production, coordinated manufacturing solutions for your custom parts.
View All Services →
Precision parts for your tight tolerances and complex geometry.
Tooling and molding for your repeat plastic parts.

Metal casting options for your part and production volume.

Cutting, forming and welding for your fabricated parts.

Custom profiles for your section, length and finish requirements.

Finishes for your appearance, corrosion and wear requirements.

Sub-assemblies and final builds for your production program.

Production tooling built around your process and volume.

Prototype parts to check fit, function and design.
DFM, process planning and production support for your project.
Inspection, documentation, inventory and delivery planning for your program.
Choose air- or liquid-cooling components around your thermal and mechanical requirements.

Manufacturing support for your cold plates, manifolds and cooling assemblies.

Find components for your power electronics, energy, laser and telecom application.

Components for your electronic systems.
Start with your functional and quality requirements.
Build around your operating environment.
From prototype to production, review material performance, manufacturability and cost for your part.
Review grade, temper and finish for your metal parts.
AluminumStrength, weight and machining›
Stainless SteelCorrosion and finish requirements›
Carbon & Alloy SteelDiscuss grade and heat treatment›
Tool SteelDiscuss tooling and wear needs›
TitaniumReview grade and part geometry›
Copper & Brass & BronzeDiscuss conductivity and machining›Match your polymer to function, process and environment.
ABSReview enclosure and molding needs›
Polycarbonate (PC)Discuss clarity and impact needs›
Nylon (PA)Review moisture and wear conditions›
POM / AcetalReview fit and sliding features›
PEEKDiscuss operating conditions›
PTFEReview friction and chemical exposure›
ULTEM / PEIDiscuss thermal and electrical needs›Confirm grade availability and application requirements.
TPU / TPEReview flexibility and processing›
EPDMReview weathering and chemical exposure.›
NBRReview oil and fuel exposure.›
FKMReview temperature and chemical exposure.›
G10 / FR4Review insulation and laminate needs›
CompositesReview stiffness, weight and laminate.›Customer-Specified MaterialsConfirm your grade and requirements.›Other Specialty MaterialsDiscuss your application and grade.›Practical guidance for your part geometry and material decisions.
Prepare your process, budget and sourcing questions.
Build your knowledge before production.
Learn who we are and how we operate.
Find our U.S. support team or start a conversation.
YOUR INTERFACES · YOUR CONDITIONS · YOUR ACCEPTANCE
Match your cold plate to the heat-source layout and the liquid loop it will actually use. Define coolant, flow, pressure-drop allowance, mounting and acceptance requirements together before committing to a channel or joining route.

Illustrative component concept
Critical geometry & interfaces
Grades, condition & compatibility
Defined route & final state
Agreed methods & records
Your liquid cold plate has to fit the heat-source layout and the loop it will actually use. Review these four inputs together before selecting how to manufacture it.

Show power by location, contact footprint, TIM and the temperature reference point.

Identify fluid chemistry, concentration, inlet temperature range and any cleanliness requirements.

Provide operating flow and the available cold-plate pressure-drop allowance, including defined measurement boundaries.
Illustrative scale; not test data. View full fixture →

Specify port thread standard, sealing method, mounting datums and clearance for fittings and tools.
Illustrative engineering concepts
Review construction and acceptance together. Your drawing and operating conditions determine the feasible route; the images illustrate structures, not confirmed manufacturing or test capability.

Review channel geometry, sealing path, fasteners and service access.
Review route requirements →
Review internal inserts, mating surfaces, material system and final fit.
Review route requirements →
Review weld access, support, material and post-joining machining.
Review route requirements →
Record the agreed material, joining method, final machining and inspection state in the controlled project specification.
Review route requirements →Illustrative engineering concepts
A machined channel with a sealed cover, a brazed internal structure and a friction stir welded cover have different design and acceptance needs. Your drawing review should compare wetted materials, joining access, final flatness and service requirements rather than selecting a process from appearance alone.
Bulk stock properties help you review conduction and mass. These are sourced material references, not LK MFG part tests, approved material substitutions or post-joining performance guarantees.
Hydro 6061-T6 at 25°C; Alumeco 3003 rolled typical; temperature and temper not stated for this physical-property entry. KME Cu-ETP annealed at 20°C.
Calculate finished mass from the actual geometry. A material conductivity difference does not establish a device-temperature reduction.
| Grade | European reference | Si | Fe | Cu | Mn | Mg | Zn | Al |
|---|---|---|---|---|---|---|---|---|
| 6061 | EN AW-6061 · AlMg1SiCu | 0.40–0.80 | ≤0.70 | 0.15–0.40 | ≤0.15 | 0.80–1.20 | ≤0.25 | Balance |
| 3003 rolled | EN AW-3003 · AlMn1Cu | ≤0.60 | ≤0.70 | 0.05–0.20 | 1.0–1.5 | — | ≤0.10 | Balance |
| C11000 | Cu-ETP · CW004A | — | — | ≥99.90 | — | — | — | — |
Selected elements only. Dash means not specified in this summary, not zero. 6061: Cr 0.04–0.35%, Ti ≤0.15%; 3003: Ti ≤0.05%; Mg/Cr not listed in the cited selected composition. C11000: O ≤0.040%; do not relabel Cu-ETP as oxygen-free copper. Aluminum other elements ≤0.05% each / ≤0.15% total. The purchasing standard and certificate govern. Confirm product form, temper, joining compatibility and required final condition.
Sources: Hydro 6061 → · Alumeco 3003 → · KME Cu-ETP →
Use calculations to frame your questions. Request measured curves or CFD only with an agreed geometry, boundary conditions and validation scope. Every example here is illustrative.
Illustrative R budget = (75°C − 25°C)/Q, using a chosen 50 K allowance. Define the actual temperature points and interfaces. This is not a measured cold plate curve.
Chosen example: 75°C limit minus a reference of 25, 35 or 45°C gives 50, 40 or 30 K. Define whether your reference is ambient, inlet fluid or another measurement point.
A conceptual path, not a CFD result. Agree heat-source area, power, contact stack, sensor locations, fluid condition, inlet temperature and flow.
Separate your thermal contact faces, sealing interfaces and wetted passages. Confirm the specified final condition with the mating assembly.

Identify thermal contact pads and agreed coating exclusions.

Mask critical fits and sealing faces when required; specify final dimensions.

Agree residues, debris control and port protection appropriate to your application.
A finish is not a universal cooling improvement. Confirm its purpose, compatibility and inspection state. Review surface finishing options →
Illustrative engineering concepts
Put the dimensions that control sealing, assembly fit and heat transfer on your drawing.

User-supplied product rendering, retouched
Heat-source map, TIM and clamping stack
Thread designation, seal land and fitting engagement
Hole pattern, datum scheme and tool access
Joining access, wall thickness and cleaning scope
Flatness, masking, protected interfaces and inspection state
Review the final component, its liquid loop and the evidence your project needs before production.
Review every wetted material, seal and treatment with your coolant chemistry, concentration, temperature and service life.
Controlled drawing and the relevant service conditions.
Agreed method, inspection state, limits and required records.

Illustrative engineering concept
For your liquid cold plate pressure drop requirement, define flow, fluid condition and the two pressure measurement locations.
Controlled drawing and the relevant service conditions.
Agreed method, inspection state, limits and required records.

Illustrative engineering concept
Map channel routing to the heat-source layout. Review branch restrictions and possible bypass rather than using total flow alone.
Controlled drawing and the relevant service conditions.
Agreed method, inspection state, limits and required records.

Illustrative engineering concept
Include the thread designation, sealing face, seal material and fitting engagement. Thread size alone does not define a leak-tight connection.
Controlled drawing and the relevant service conditions.
Agreed method, inspection state, limits and required records.

Illustrative engineering concept
Specify liquid cold plate flatness tolerance on the final joined and finished part with datums, restraint and inspection method.
Controlled drawing and the relevant service conditions.
Agreed method, inspection state, limits and required records.

Illustrative engineering concept
Dimensional, leak, proof-pressure, hydraulic and thermal checks answer different questions. Identify the required checks individually.
Controlled drawing and the relevant service conditions.
Agreed method, inspection state, limits and required records.

Illustrative engineering concept
Confirm revision, interfaces and operating inputs.
Agree materials, joining and final machining.
Review the finished component and assembly fit.
Assess specified dimensions, joints and test records.
Release the accepted revision, packaging and repeat-order scope.

Illustrative component concept
Your liquid cold plate prototype should separate dimensional approval, sealing checks, flow and pressure-drop checks, and thermal validation. For liquid cold plate leak testing, agree method, medium, pressure or vacuum condition, duration, temperature and allowable leakage. A passed leak test does not prove cooling performance.
Project suitability, manufacturing scope and required records are confirmed from your drawing. These are application review topics, not customer case studies or system certifications.

Match module footprint, insulation, clamp load and the heat-source map.
Review switching heat loads, service temperatures and mounting interfaces.
Agree operating conditions and the component acceptance scope.
Review temperature stability requirements, coolant or airflow and service access.
Review the exact device footprint, coolant connections and loop conditions.
Identify instrument clearances, heat loads and service access.
Review electrical isolation, contact layout and the specified coolant circuit.
Match the enclosure interfaces, fluid connections and maintenance plan.
Illustrative assembly and application review topics; no customer case study, system certification or universal fit claim. Explore application requirements →
Ask your quote to separate component manufacturing, joining, finishing, inspection and any independently agreed validation. The drawing review confirms availability, quantities and delivery scope.
Provide the fluid name and chemistry, concentration, operating and storage temperatures, inlet temperature range, required flow and any cleanliness or corrosion-control requirements. List every wetted material in the intended loop.
No. A leak test checks sealing under specified conditions. Thermal performance needs a defined heat-source map, power, interfaces, coolant conditions, flow and temperature measurements.
Specify the thread standard and size, sealing method and face geometry, seal material, fitting engagement, installation access and any assembly torque requirement agreed with the fitting supplier.
Submit the channel and cover geometry, material, ports, sample quantity and acceptance plan. CNC machining is one part of the route; joining, cleaning, sealing and final inspection must also be scoped.
Compare when the internal geometry, materials, cover access, final flatness or production plan changes the joining decision. Each route needs a drawing-specific feasibility and acceptance review.
Only after reviewing the specific heat map, temperature limits, coolant, mounting and loop conditions. A similar outside shape does not establish application suitability.